AQA RP4 context · practical reasoning

Membranes: evaluate a pigment-leakage comparison

Investigate how treatment temperature relates to pigment released from comparable coloured plant tissue over a fixed interval.

Absorbance is measured after 10 min with the same instrument settings and suitable blanking. Readings are dimensionless. Separate tissue pieces are used; the colour reading is a leakage indicator, not a directly measured membrane permeability coefficient.

Questions only · Matched example · 3 readings per condition.

Return to the workbench

Plan the comparison

What should be varied?

  • Select a different colorimeter wavelength for each treatment temperature.
  • Increase the mass of tissue as treatment temperature increases.
  • Vary treatment temperature between otherwise comparable tissue samples.

Which recording method supports the stated temperature comparison?

  • Record how many tissue pieces show a visible colour change.
  • Record solution absorbance after the same 10 min treatment.
  • Record solution colour by eye under different lighting at each temperature.

Which control approach is useful?

  • Standardise tissue amount, cut surface, preparation and treatment duration.
  • End each treatment when the solution reaches the same visible colour.
  • Rinse the pieces for cooler treatments, but leave pieces for hotter treatments unrinsed.

Calculate from evidence

Comparable tissue amount and preparation are used.

Absorbance (dimensionless) after 10 min · 3 readings per condition · Matched example
Temperature / °CReading 1Reading 2Reading 3
200.050.060.07
300.090.10.11
400.170.180.19
500.390.40.41
600.690.70.71

Mean absorbance = sum of readings ÷ number of readings. A difference subtracts the lower-temperature mean from the higher-temperature mean. Give numerical answers to about three significant figures.

Calculate the mean absorbance at 40 °C.

Calculate mean absorbance at 50 °C minus mean absorbance at 20 °C.

Evaluate the comparison

Explain why a larger absorbance at a higher temperature does not by itself identify a particular molecular membrane change. Evaluate the tissue-amount confound and propose a stronger comparison.

Use the alternate example below alongside the data above.

Absorbance (dimensionless) after 10 min · 3 readings per condition · Tissue amount increases with temperature
Temperature / °CReading 1Reading 2Reading 3
200.050.060.07
300.140.150.16
400.290.30.31
500.690.70.71
600.9911.01

Original authored examples, not real experimental predictions, official marks or a laboratory protocol.