What should be varied?
- Select a different colorimeter wavelength for each treatment temperature.
- Increase the mass of tissue as treatment temperature increases.
- Vary treatment temperature between otherwise comparable tissue samples.
AQA RP4 context · practical reasoning
Investigate how treatment temperature relates to pigment released from comparable coloured plant tissue over a fixed interval.
Absorbance is measured after 10 min with the same instrument settings and suitable blanking. Readings are dimensionless. Separate tissue pieces are used; the colour reading is a leakage indicator, not a directly measured membrane permeability coefficient.
Questions and answers · Matched example · 3 readings per condition.
Comparable tissue amount and preparation are used.
| Temperature / °C | Reading 1 | Reading 2 | Reading 3 |
|---|---|---|---|
| 20 | 0.05 | 0.06 | 0.07 |
| 30 | 0.09 | 0.1 | 0.11 |
| 40 | 0.17 | 0.18 | 0.19 |
| 50 | 0.39 | 0.4 | 0.41 |
| 60 | 0.69 | 0.7 | 0.71 |
Mean absorbance = sum of readings ÷ number of readings. A difference subtracts the lower-temperature mean from the higher-temperature mean. Give numerical answers to about three significant figures.
Use the alternate example below alongside the data above.
| Temperature / °C | Reading 1 | Reading 2 | Reading 3 |
|---|---|---|---|
| 20 | 0.05 | 0.06 | 0.07 |
| 30 | 0.14 | 0.15 | 0.16 |
| 40 | 0.29 | 0.3 | 0.31 |
| 50 | 0.69 | 0.7 | 0.71 |
| 60 | 0.99 | 1 | 1.01 |
Vary treatment temperature between otherwise comparable tissue samples. Temperature is the intended independent variable.
Record solution absorbance after the same 10 min treatment. Comparable instrument conditions and duration support a pigment comparison.
Standardise tissue amount, cut surface, preparation and treatment duration. These factors affect leakage independently of the intended temperature comparison.
Mean = (0.17 + 0.18 + 0.19) ÷ 3 = 0.18. Mean absorbance = 0.18; absorbance is dimensionless.
Absorbance difference = 0.4 − 0.06 = 0.34. This is not a permeability coefficient.
A larger absorbance is consistent with more pigment in the sampled liquid under suitable measurement conditions. It is not a direct permeability coefficient and does not distinguish lipid changes from particular protein changes. Increasing tissue amount with temperature provides another reason for higher readings. Standardise tissue amount, cut surface, preparation, duration and instrument conditions; use separate pieces to assess variation. More repeats do not remove a systematic tissue-amount confound.
Original authored examples, not real experimental predictions, official marks or a laboratory protocol.