What should be varied?
- Use more chloroplast extract at the brighter light settings.
- Vary incident light intensity between otherwise comparable chloroplast assays.
- Increase assay duration at the dimmer light settings.
AQA RP8 context · practical reasoning
Investigate light intensity and a redox-indicator absorbance change in a supplied chloroplast assay.
Every assay starts at absorbance 0.80. Final absorbance is recorded after 120 s. A decline is used as an indicator of electron-transfer activity under the assay conditions, not a direct measurement of whole-leaf carbon fixation. Values are authored examples.
Questions and answers · Matched example · 3 readings per condition.
Extract concentration, starting absorbance and temperature are comparable.
| Light intensity / μmol photons m⁻² s⁻¹ | Reading 1 | Reading 2 | Reading 3 |
|---|---|---|---|
| 0 | 0.79 | 0.8 | 0.81 |
| 50 | 0.67 | 0.68 | 0.69 |
| 100 | 0.54 | 0.55 | 0.56 |
| 150 | 0.44 | 0.45 | 0.46 |
| 200 | 0.39 | 0.4 | 0.41 |
Absorbance decline = 0.80 − mean final absorbance. Decline rate = decline ÷ 120 s. Give numerical answers to about three significant figures.
Use the alternate example below alongside the data above.
| Light intensity / μmol photons m⁻² s⁻¹ | Reading 1 | Reading 2 | Reading 3 |
|---|---|---|---|
| 0 | 0.79 | 0.8 | 0.81 |
| 50 | 0.63 | 0.64 | 0.65 |
| 100 | 0.44 | 0.45 | 0.46 |
| 150 | 0.24 | 0.25 | 0.26 |
| 200 | 0.14 | 0.15 | 0.16 |
Vary incident light intensity between otherwise comparable chloroplast assays. Light is the intended independent variable in this assay question.
Record initial and final indicator absorbance over the same 120 s. A change over a known duration supports an assay-rate comparison.
Keep extract concentration, temperature and duration comparable. These reduce changes unrelated to incident light.
Mean = (0.54 + 0.55 + 0.56) ÷ 3 = 0.55. Absorbance decline = 0.8 − 0.55 = 0.25.
Decline rate = 0.25 ÷ 120 = 0.0020833 s⁻¹. This is an assay proxy, not direct carbon fixation.
The confounded example has a larger indicator decline at the higher light settings, but extract concentration also increases. A light-only effect cannot be isolated from that design. Keep extract concentration, starting indicator conditions, temperature and duration comparable while varying light. Indicator reduction supports an electron-transfer comparison in this assay; it does not directly measure whole-plant carbon fixation or establish that one light level is optimal in every plant.
Original authored examples, not real experimental predictions, official marks or a laboratory protocol.